WATCH THE FILM · 16 minutes 46 seconds
UK Consumer Units Explained
Go through the house door and watch the connections build, current arrows move and components rub out and redraw. English captions, 22 chapters and a transcript are available below.
Explanatory cutaway: internal work and replacement MUST use a qualified electrician.
Press Play to start. English captions and full screen are available in the player.
Read the full consumer unit guide
Jump to a chapter
Read the full transcript
The next part of the journey
Welcome back to the home of EPHG. We will follow the meter tails into the consumer unit, draw its internal connections, and see how the protective devices affect current. The cutaway is a teaching illustration, not an installation sequence. In a real home, opening this equipment, changing wiring or replacing components must be done by a qualified electrician competent for the work. We will keep ordinary householder checks clearly separate.
The outgoing meter tails
These substantial insulated cables carry the supply onwards from the meter. In our example, they pass through a separate isolator before entering the home. Other arrangements can include additional switching or protection. The live and neutral conductors are not the same as the earthing conductor. Earthing provides a protective connection; it is not intended to carry the normal load current. The route shown here is illustrative. Never disconnect tails, break seals or remove the main supply fuse yourself. Work involving meter connections or sealed equipment needs coordination with the appropriate authorised parties.
Through the front door
We will leave the meter in place and go through the front door. As we move into the hall, the drawing follows the supply towards the consumer unit on the inside wall. Its position and cable route are examples; homes differ. From here, we can see how each part connects to the next.
Meet the consumer unit
The consumer unit distributes electricity to circuits such as lights, sockets and cooking equipment. Its enclosure normally keeps the live connections covered. For this explanation, the cover fades away so that we can see the main switch, protective devices, neutral connections and earth bar. The rail supports the devices; it is not the circuit's normal current path. We will build the drawing in stages to explain their relationships. Do not remove your own cover to follow along. Opening it and working inside must be left to a qualified electrician.
Build the connections
First, follow the line and neutral supply paths through the example double pole main switch. Both then pass through the shared RCCB. Its line output supplies a busbar, which distributes the connection to the individual circuit breakers. Each breaker feeds its circuit's load. The neutral from each of those circuits returns to this group's neutral bar and back through the same RCCB. A different RCCB group needs its own correctly separated neutral arrangement. The drawing uses simplified routes and modern colour conventions. It does not specify cable sizes, terminals or an installation design to copy.
Follow the current
Now follow the arrows around a complete circuit. In this illustrated half cycle, current passes through the line path and load, returning through neutral. In the next half cycle, the directions reverse together. United Kingdom mains is alternating current at a nominal fifty complete cycles each second. We slow the arrows down so you can follow them. They represent conventional current direction, not particles travelling at the pictured speed or a measurement of current size. Energy is still delivered to the appliance. Neutral is a current carrying conductor; its colour or name does not make it safe to touch.
The protective earth path
The protective conductor follows a separate route to the earth bar and the installation's earthing arrangement. It does not pass through the main switch or the RCD's current sensing path. The metal enclosure also needs its protective connection. Earth is not the intended normal load return, although some equipment can produce small protective conductor currents during normal operation. If a fault connects line to an exposed metal case, the protective path can carry fault current back towards the source so protection can operate. Earthing arrangements vary. Do not add a neutral to earth link inside a consumer unit.
The main switch
Watch the example main switch open its line and neutral paths. The load circuit is interrupted and our normal-current arrows stop. A plain main switch is a manual control; it does not automatically detect an overload, short circuit or residual current fault. Its ampere rating is not a setting for the householder to adjust. The incoming side can remain live. Solar panels, batteries, another board or backup equipment can introduce additional supplies. Off is not proof that every part is dead. A qualified electrician must identify the supplies and carry out the required safe isolation and verification before internal work.
MCB: too much current
A miniature circuit breaker, or MCB, protects its circuit against excessive current. An overload means the connected demand is too high for that circuit's protection. A short circuit is an unintended low resistance connection which can allow a very large current. Watch the breaker open the affected line path. It helps protect the circuit, but does not provide the additional residual current shock protection of a thirty milliamp RCD. A trip does not prove the breaker is faulty. Never fit a larger breaker or fuse to stop tripping. Diagnosis, internal testing and replacement must be done by a qualified electrician.
RCD: an imbalance in current
Residual current device, or RCD, is a family name. This RCCB compares the current in the line and neutral paths passing through it. Normally the outgoing and returning currents balance. Now the drawing shows some current taking a different route through a fault to a metal case and the protective conductor. Less returns through the monitored neutral path. The RCCB detects that imbalance and disconnects when its operating conditions are met. The arrows stop on the disconnected load side. It reduces certain shock risks, but cannot prevent every shock. It does not itself provide overload or short circuit protection.
RCBO: combined protection
We will now rub out the shared RCCB, its circuit breakers and the associated line and neutral routes. The enclosure, main switch and protective earth connections stay in the drawing. We redraw the circuits with individual RCBOs. Each RCBO combines residual current and overcurrent protection. Its own circuit's line and neutral pass through the correct sensing path. Watch the new neutral routes as well as the line connections. This is an explanatory change of arrangement, not a simple component swap. A qualified electrician must check the design, compatibility, connections and testing before any real alteration.
Why boards look different
Compare what happens when one circuit develops a fault. With a shared RCCB, all circuits in its protected group can lose power together. In our individual RCBO example, the affected circuit disconnects while the others remain supplied. That illustrates why separate protection can reduce the extent of an outage; it is not a promise that only one device can ever operate. Consumer units can also contain mixed arrangements. An electrician must use combinations verified for the particular assembly. Parts that look similar, or even share a brand name, are not automatically interchangeable.
Read the label carefully
On this example breaker, B thirty two means a B overcurrent characteristic and a thirty two ampere rating. It is not an instruction to change it to a C curve. On this example RCCB, sixty three amperes is its rated carrying current; thirty milliamperes is its rated residual operating current. Those are different properties. The letters on residual current devices describe the current waveforms they detect. You may see types A C, A, F or B. Residual current Type B is unrelated to the B in B thirty two. Electronic loads need suitable protection, selected by the installer using the equipment instructions and installation design.
SPD: short voltage surges
The surge protective device, or SPD, has a different connection and job. It is a protective branch, not a device through which all normal load current passes. It helps limit brief overvoltages from switching events or lightning effects. It cannot guarantee protection from every lightning event. Read its condition indicator using that product's instructions. In our explanation, a device needing attention is erased and a replacement drawn in. This represents an electrician's work on correctly isolated equipment, not a householder pulling out a cartridge. Normal power can remain available even when surge protection needs attention.
AFDD: detecting arcing faults
An arc fault detection device, or AFDD, recognises characteristic electrical arcing patterns and disconnects to reduce the risk of fire from those faults. Arcing can occur at damaged conductors or poor connections. We erase one example device and redraw a combined AFDD and RCBO to explain the extra function. This is not a claim that the devices are interchangeable. Other models combine arc detection with an MCB instead, so residual current protection must not be assumed. A qualified electrician must select compatible equipment and investigate faults. Test procedures and diagnostic indicators depend on the actual model.
Older fuseboards
Older homes may have fuse carriers rather than modern toggle breakers, and may lack some protections we have just discussed. Do not remove a carrier or attempt to renew fuse wire as part of this lesson. Age and appearance alone do not establish the condition of an installation. An older board is not automatically an immediate emergency, but its condition and protective measures need an electrician's assessment. An electrical installation condition report records findings from professional inspection and testing. Discuss appropriate improvements using those findings, rather than assuming every old board is safe or every old board must immediately be replaced.
Using the test button
We put the protective cover back in our illustration before showing normal user controls. The button marked T or Test on an RCCB or RCBO exercises its test function. Both belong to the RCD family. Follow the installed device's instructions, including how and when to test. Many domestic labels specify six monthly testing, but some devices require a different interval. Plan the intentional power interruption, especially for medical or other essential equipment. If the expected operation does not happen under the specified conditions, contact a qualified electrician. A successful button test is not a complete test of the wiring, earthing or installation.
A circuit trips: look first
Suppose a circuit loses power while a portable appliance is in use. First look for danger, without touching suspect equipment. Burning smells, scorching, unusual heat, damaged covers, exposed parts or water mean stop and get appropriate help. Do not touch a wet consumer unit. If there is a fire, get out, stay out and call nine nine nine. With no danger signs, note which rooms lost power, which labelled device operated, and what was running. Check the network's outage information when appropriate. Other houses having power does not prove your incoming supply is healthy. A switch position alone cannot identify the fault.
A limited check, then stop
If an obvious suspect is an accessible portable appliance, switch it off and unplug it only if safe. Leave it unplugged. Do not pull out built in equipment, remove covers or disconnect fixed wiring. On dry, undamaged, accessible equipment, a reset may be reasonable if the device's instructions permit it. Our conservative rule for this lesson is one attempt after removing an obvious suspect load. Use only the normal control as instructed. If it will not latch, trips again, or the cause is unclear, leave the affected circuit off and contact a qualified electrician. Never force, hold or bypass a protective device. Do not reconnect a suspect appliance just to reproduce the fault. Restored power does not prove the cause has been repaired.
Who to contact
Repeated tripping, failed test operation and concerns about the consumer unit must be investigated by a qualified electrician. Give them the circuit label, device information and your observations. If you rent, report the problem to your landlord or managing agent. For a network power cut in England, Scotland or Wales, call one zero five. In Northern Ireland, use NIE Networks on zero three four five seven, six four three, six four three. For meter readings, prepayment or account problems, contact your electricity supplier. Keep an emergency plan for essential equipment; your healthcare or equipment provider can help you prepare for an interruption.
Ownership and electrical work
The property owner normally arranges care of the consumer unit and the home's installation through a qualified electrician. The network and metering equipment are managed separately. Responsibility for cables called meter tails depends on which side of the meter they serve and the local arrangement. Flats, shared supplies and private networks can add further boundaries. Your supplier, network operator and electrician can establish who needs to attend. Owning equipment does not make work on it safe to do yourself. Inspection duties and building requirements also vary across the United Kingdom, so location and tenancy matter when seeking advice. Opening the unit, changing its connections or replacing its parts must be done by a qualified electrician competent for that work.
Know your controls
You do not need to become an electrician to understand your consumer unit. Learn where it is, keep its labels and instructions available, plan the recommended user tests, and recognise when to stop. The chapter links below let you revisit each device, read the transcript and explore the related EPHG guides. This house will remain our guide as we follow the circuits further into the home.
Sources, scope and example arrangements
Research checked on 13 November 2026. The camera enters the original house and the consumer-unit cover fades away for an explanatory cutaway. Line, neutral and protective-earth routes build progressively. Components and their associated routes are erased and redrawn to compare arrangements. The cover returns before ordinary user checks. This is a representative UK example, not an installation or replacement procedure. Brands, switch positions, test procedures and indicators vary: follow the instructions for your own equipment.
The arrows show conventional current with the motion deliberately slowed. UK mains has a nominal frequency of 50 complete cycles per second; line and neutral directions reverse each half-cycle in the simplified example. Protective earth is separate from the normal load return, although equipment can produce protective-conductor current in normal use. Fault-return arrangements vary between installations.
Each shared RCCB group needs the correct separate neutral return. An RCBO arrangement changes the neutral paths as well as the devices; replacement is not a simple visual swap. Compatibility must be verified for the particular assembly, even when parts share a brand. The SPD is shown as a protective branch; its connections, short-circuit protection and indicators depend on the product. Opening the unit, internal testing, alterations and replacement must use a qualified electrician competent for the work.
Metering and isolation responsibilities vary, including between Great Britain and Northern Ireland and in shared buildings. The outgoing installation, consumer unit and home circuits normally fall to the property owner or landlord to maintain through a qualified electrician competent for the work. Confirm responsibility for an isolator and short meter connections before work. Never remove the supply fuse, break seals or disconnect cables yourself.
The lesson explains device functions without claiming that every existing home must have the latest layout. Older equipment needs assessment of its condition and protection. Electrical installation standards, building-control rules and landlord duties are distinct; requirements depend on the work and UK nation.
- IET: consumer units — main switches, circuit protection and user checks.
- IET: consumer units and protective-device FAQs and current wiring-regulations edition information.
- KSB: alternating current and Hager: RCBO application guidance (PDF) — AC principles, 50 Hz ratings and differing RCBO constructions. Professional connection instructions are not homeowner tasks.
- IET: earthing and bonding FAQs and protective-conductor currents — the separate protective path, normal leakage and installation differences.
- BEAMA: residual-current device guidance — how line and neutral sensing relates to protective-device operation.
- IET: replacing devices in an assembly and BEAMA: safe device selection — why size, appearance or a matching brand do not establish compatibility.
- Schneider Electric: the parallel SPD branch and IET: manufacturer-specific SPD protection — the branch shown is an example; design and replacement follow the actual product instructions.
- IET: different RCD types — device principles; the older article is not a statement of every current installation requirement.
- Hager: circuit protection, surge protection and arc-fault detection — examples of different protective functions.
- Schneider Electric: RCBO test intervals — why the installed device’s instructions matter.
- Electrical Safety First: common electrical questions and electrical safety after flooding — recurring trips and when to stop.
- Electrical Safety First: assessing an existing installation — why an older consumer unit needs assessment of its condition and protection.
- UK Power Networks: trip switches and equipment responsibilities.
- IET: instructions for modern domestic installations — solar PV, storage, additional supplies and installation-specific shutdown information.
- UK Power Networks: planning for loss of electricity — medical equipment and backup arrangements.
- SP Energy Networks: power-cut contacts, NIE Networks: power cuts in Northern Ireland and London Fire Brigade: when to call 999.
Qualified technical review not recorded. No review of this guide and film by a named qualified electrician is claimed. Editorial approval does not establish a professional electrical review.
An original EPHG pencil-style film with computer-generated narration. The diagrams are explanatory and are not installation instructions.